Describes standard Color Palette types, used to facilitate Multi-language support and client display. "Custom" Type shall be used when Color Palette Name does not match any of the types included in the standard classification. Describes a Color Palette element. User readable Color Palette name. Unique identifier of this Color Palette. Indicates Color Palette Type. Use tth:ColorPaletteType. Used for multi-language support and display. Type describing a NUC Table element. User reabable name for the Non-Uniformity Correction (NUC) Table. Unique identifier of this NUC Table. Low Temperature limit for application of NUC Table, in Kelvin. High Temperature limit for application of NUC Table, in Kelvin. Type describing the Cooler settings. Indicates whether the Cooler is enabled (running) or not. Number of hours the Cooler has been running (unit: hours). Read-only. Describes valid ranges for the thermal device cooler settings. Only applicable to cooled thermal devices. Indicates the Device allows cooler status to be changed from running (Enabled) to stopped (Disabled), and viceversa. Holds default values that will be used in measurement modules when local parameters are not specified for the module (these are still required for valid temperature calculations). Having ReflectedAmbientTemperature, Emissivity and DistanceToObject as mandatory ensures minimum parameters are available to obtain valid temperature values. Reflected Ambient Temperature for the environment in which the thermal device and the object being measured is located. Emissivity of the surface of the object on which temperature is being measured. Distance from the thermal device to the measured object. Relative Humidity in the environment in which the measurement is located. Temperature of the atmosphere between the thermal device and the object being measured. Transmittance value for the atmosphere between the thermal device and the object being measured. Temperature of the optics elements between the thermal device and the object being measured. Transmittance value for the optics elements between the thermal device and the object being measured. Describes valid ranges for the different radiometry parameters required for accurate temperature calculation. Valid range of temperature values, in Kelvin. Valid range of emissivity values for the objects to measure. Valid range of distance between camera and object for a valid temperature reading, in meters. Valid range of relative humidity values, in percentage. Valid range of temperature values, in Kelvin. Valid range of atmospheric transmittance values. Valid range of temperature values, in Kelvin. Valid range of external optics transmittance. Current Color Palette in use by the Thermal Device. Polarity configuration of the Thermal Device. Current Non-Uniformity Correction (NUC) Table in use by the Thermal Device. Cooler settings of the Thermal Device. Current Thermal Settings for the VideoSource. Reference token to the thermal VideoSource. Global Parameters for Radiometry Measurements. Shall exist if Radiometry Capability is reported, and Global Parameters are supported by the device. List of Color Palettes available for the requested Thermal VideoSource. List of Non-Uniformity Correction (NUC) Tables available for the requested Thermal VideoSource. Specifies Cooler Options for cooled thermal devices. Specifies valid ranges and options for the global radiometry parameters used as default parameter values for temperature measurement modules (spots and boxes). The capabilities of the thermal service are returned in the Capabilities element. Indicates whether or not radiometric thermal measurements are supported by the thermal device. Reference token to the VideoSource for which the Thermal Configuration Options are requested. Valid ranges for the Thermal configuration parameters that are categorized as device specific. Reference token to the VideoSource for which the Thermal Settings are requested. Thermal Settings for the VideoSource that was requested. This element contains a list of thermal VideoSource configurations. Reference token to the VideoSource for which the Thermal Settings are configured. Thermal Settings to be configured. Reference token to the VideoSource for which the Thermal Radiometry Options are requested. Valid ranges for the Thermal Radiometry parameters that are categorized as device specific. Reference token to the VideoSource for which the Radiometry Configuration is requested. Radiometry Configuration for the VideoSource that was requested. Reference token to the VideoSource for which the Radiometry settings are configured. Radiometry settings to be configured. Returns the capabilities of the thermal service. The result is returned in a typed answer. Gets the valid ranges for the Thermal parameters that have device specific ranges. This command is mandatory for all devices implementing the Thermal service. The command shall return all supported parameters and their ranges, such that these can be applied to the SetConfiguration command.
Gets the Thermal Configuration for the requested VideoSource. Gets the Thermal Configuration for all thermal VideoSources of the Device. Sets the Thermal Configuration for the requested VideoSource. Gets the valid ranges for the Radiometry parameters that have device specific ranges. The command shall return all supported parameters and their ranges, such that these can be applied to the SetRadiometryConfiguration command.
Gets the Radiometry Configuration for the requested VideoSource. Sets the Radiometry Configuration for the requested VideoSource.